EasyEDA Pro API Skill
Control EasyEDA Pro (嘉立创EDA专业版) programmatically through AI. This skill provides:
- Complete API reference — 120 classes, 62 enums, 70 interfaces, 19 type aliases
- WebSocket bridge — Execute code in the running EasyEDA Pro client
- Code patterns — Common operations for PCB, schematic, library, and project management
- Document source format reference — File format specifications for project, schematic, and PCB sources when users need to analyze or modify EasyEDA document source directly instead of using the API
This skill supports not only live debugging in EasyEDA, but also EasyEDA extension development. During EasyEDA extension development, AI agents can use the extension-related documentation, API references, type information, usage examples, and bridge-based debugging capabilities provided by this skill to look up APIs, write code, and validate behavior during integration and debugging.
Architecture
┌───────────┐ HTTP/WS ┌─────────────────┐ WebSocket ┌───────────┐
│ AI Agent │ ◄───────────► │ Bridge Server │ ◄───────────► │ EasyEDA │
│ │ Port Range │ (Node.js) │ Port Range │ (Client) │
└───────────┘ 49620-49629 └─────────────────┘ 49620-49629 └───────────┘
The server auto-selects an available port from 49620-49629 on startup.
Both AI and EDA clients auto-discover the server by scanning the port range
and verifying a handshake (service: "easyeda-bridge").
Quick Start
1. Command Triggers
When user says "嘉立创EDA,启动!", "立创EDA,启动!", or "EDA,启动!":
IMPORTANT: Session initialization — Reply immediately with this exact text to set the correct session title:
📋 EasyEDA Session
Then proceed with the setup steps below.
2. Install dependencies (if needed)
cd ${CLAUDE_SKILL_DIR} && npm install
3. Start bridge server
⚠️ IMPORTANT: The bridge server must run in the background. Do NOT run it in the foreground, or the AI will block waiting for the server to exit.
# Check if bridge is already running
for port in $(seq 49620 49629); do
resp=$(curl -s http://localhost:$port/health 2>/dev/null)
if echo "$resp" | grep -q '"easyeda-bridge"'; then
echo "Bridge already running on port $port"
BRIDGE_PORT=$port
break
fi
done
# Start bridge if not running
if [ -z "$BRIDGE_PORT" ]; then
node ${CLAUDE_SKILL_DIR}/scripts/bridge-server.mjs &
sleep 2
# Find the port bridge is running on
for port in $(seq 49620 49629); do
resp=$(curl -s http://localhost:$port/health 2>/dev/null)
if echo "$resp" | grep -q '"easyeda-bridge"'; then
BRIDGE_PORT=$port
break
fi
done
fi
echo "Bridge running on port: ${BRIDGE_PORT:-unknown}"
4. Connect EasyEDA
Install the run-api-gateway.eext extension in EasyEDA Pro. Download link:
After the extension is loaded, it will automatically establish the WebSocket connection.
5. Verify connection and select EDA window
# Check bridge and EDA connection status
curl http://localhost:${BRIDGE_PORT:-49620}/health
# List all connected EDA windows
curl http://localhost:${BRIDGE_PORT:-49620}/eda-windows
The /eda-windows response looks like:
{
"windows": [
{ "windowId": "abc-123", "connected": true, "active": true },
{ "windowId": "def-456", "connected": true, "active": false }
],
"activeWindowId": "abc-123",
"count": 2
}
Handle based on window count:
- 0 windows: Tell user "No EasyEDA window is connected. Please ensure the EasyEDA extension (run-api-gateway.eext) is installed and loaded in EasyEDA. Download: https://ext.lceda.cn/item/oshwhub/run-api-gateway"
- 1 window: Auto-selected as active. Tell user: "✅ Connected! Active EDA window: abc-123. Ready to work."
- 2+ windows: Show the available windows and ask user to select:
Multiple EDA windows detected: - abc-123 (active) - def-456 Which EDA window should I use?
Select a window:
curl -X POST http://localhost:${BRIDGE_PORT}/eda-windows/select \
-H "Content-Type: application/json" \
-d '{"windowId": "abc-123"}'
After selection, confirm: "✅ Active EDA window: abc-123. Ready to work."
6. Execute code on EDA
curl -X POST http://localhost:${BRIDGE_PORT:-49620}/execute \
-H "Content-Type: application/json" \
-d '{"code": "return await eda.dmt_Project.getCurrentProjectInfo();"}'
API Documentation
The full API reference is in the references/ directory:
- references/_index.md — Master index of all classes, enums, interfaces, and types
- references/_quick-reference.md — All method signatures for rapid lookup
references/classes/— 120 class docs (DMT_, PCB_, SCH_, LIB_, SYS_, IPCB_, ISCH_*)references/enums/— 62 enum docsreferences/interfaces/— 70 interface docsreferences/types/— 19 type alias docs
How to look up API
- Start with
_index.mdto find the right class/module for the task - Read the class doc (e.g.,
references/classes/DMT_Board.md) for all methods and signatures - Use
_quick-reference.mdfor fast method signature lookup across all classes - Check enums/interfaces for parameter types and return types
Document Source Format Documentation
If the user needs to analyze or modify EasyEDA document source directly instead of using the API, use the documents in the format/ directory.
- format/index.md — Overview of the EasyEDA document source format references and version notes
format/project/— Project source structure, metadata, blobs, variants, and grouping dataformat/schematic/— Schematic source format, including structure, wires, shapes, pins, components, and tablesformat/pcb/— PCB source format, including primitives, pads and vias, shapes, text, attributes, rules, and panel data
Use these files when the task is about understanding source layout, generating compatible document source, or editing source data that will later be imported back into EasyEDA.
API Module Overview
| Prefix | Domain | Key Classes |
|---|---|---|
DMT_ | Document management | Board, EditorControl, Folder, Panel, Pcb, Project, Schematic, SelectControl, Team, Workspace |
PCB_ | PCB & Footprint | Document, Drc, Event, Layer, Net, Primitive, PrimitiveComponent, PrimitiveLine, PrimitivePad, PrimitivePour, PrimitiveVia, SelectControl |
SCH_ | Schematic | Document, Event, Primitive, PrimitiveComponent, PrimitiveWire, SelectControl |
LIB_ | Library | 3DModel, Cbb, Classification, Device, Footprint, LibrariesList, PanelLibrary, SelectControl, Symbol |
SYS_ | System | Dialog, Environment, FileManager, FileSystem, FontManager, HeaderMenu, I18n, IFrame, LoadingAndProgressBar, Log, Message, MessageBox, MessageBus, PanelControl, Setting, ShortcutKey, Storage, Timer, ToastMessage, WebSocket, Window |
IPCB_ | PCB interfaces (图元) | PrimitiveArc, PrimitiveComponent, PrimitivePad, PrimitiveFill, PrimitivePour, PrimitiveRegion, PrimitiveVia, ... |
ISCH_ | Schematic interfaces (图元) | PrimitiveArc, PrimitiveComponent, PrimitiveWire, PrimitiveText, PrimitiveRectangle, ... |
EPCB_ / ESCH_ | Enums | PrimitiveType, Layer, PadType, ... |
Code Execution Context
All code runs inside EasyEDA Pro's browser runtime as:
async function(eda) {
// Your code here — `eda` is the global EDA API object
// You MUST use `return` to send results back
// Do not add comments to the generated code, as the code is typically executed as a single line
}
Critical rules:
- The
edaobject provides access to all API modules (e.g.,eda.dmt_Board,eda.pcb_Primitive). - Always refer to the API documentation for correct usage.
- Do not add comments to the generated code, as the code is typically executed as a single line.
- Always use
returnto get results —console.logoutput is NOT captured. - All API methods returning promises must be
awaited. - Code runs in browser context — no Node.js APIs (fs, path, etc.) available.
- Use
eda.sys_Message.showToastMessage(msg)for user-visible notifications. - When reviewing API documentation and encountering enumerations, do not guess the enumeration values. You must use the enumeration members, for example:
EPCB_LayerId.TOPinstead of1for the layer parameter in PCB primitive creation.
Extension Runtime Constraints
When writing EasyEDA extensions, standard browser APIs are forbidden in the main process. Use EDA-provided alternatives:
| Purpose | ❌ Forbidden | ✅ Use Instead |
|---|---|---|
| Get user input | — | eda.sys_Dialog.showInputDialog() |
| User selection | — | eda.sys_Dialog.showSelectDialog() |
| Show message | alert() | eda.sys_Dialog.showInformationMessage() |
| Confirm action | confirm() | eda.sys_Dialog.showConfirmationMessage() |
| Toast notification | DOM manipulation | eda.sys_Message.showToastMessage() |
| Store data | localStorage (main process) | eda.sys_Storage.setExtensionUserConfig(key, value) |
| Custom UI | Manipulate host DOM | eda.sys_IFrame.openIFrame() |
| Show HTML | showInformationMessage(html) | Must use iframe |
| Open link | window.open() | eda.sys_Window.open() |
| Browser hardware API | Use in main process | Available in iframe (navigator.serial, etc.) |
Note: localStorage, window, document etc. are available inside sys_IFrame but NOT in the main extension process.
Extension ↔ IFrame Data Passing
The main extension process and sys_IFrame iframe are isolated contexts. To pass data between them:
Option A (Recommended): Use eda.sys_Storage as a bridge
// In main extension process:
await eda.sys_Storage.setExtensionUserConfig('myKey', JSON.stringify(data));
// In iframe:
const data = JSON.parse(await eda.sys_Storage.getExtensionUserConfig('myKey'));
Option B: Both contexts can access eda directly — call the same API from either side
// In iframe HTML (NOT window.parent.eda):
const info = await eda.dmt_Project.getCurrentProjectInfo();
Communication Protocol
Port Discovery
The bridge server listens on the first available port in 49620-49629. To find the server, scan the range and verify the service identity:
for port in $(seq 49620 49629); do
resp=$(curl -s http://127.0.0.1:$port/health 2>/dev/null)
if echo "$resp" | grep -q '"easyeda-bridge"'; then
BRIDGE_PORT=$port; break
fi
done
Handshake
- HTTP:
GET /healthreturns{ "service": "easyeda-bridge", "edaConnected": bool, ... } - WebSocket: On connect, server sends
{ "type": "handshake", "service": "easyeda-bridge" } - Clients MUST verify
service === "easyeda-bridge"before using the connection
Message Format
JSON messages over WebSocket / HTTP:
| Field | Type | Description |
|---|---|---|
type | "execute" | "result" | "error" | "ping" | "pong" | "handshake" | Message type |
id | string | Request UUID for matching request/response |
code | string | JavaScript code to execute (for execute type) |
result | any | Execution result (for result type) |
error | string | Error message (for error type) |
service | string | Service identifier (for handshake type) |
timestamp | number | Unix milliseconds |
Common Patterns
Project & Board Operations
// Get current project info
return await eda.dmt_Project.getCurrentProjectInfo();
// List all boards in project
return await eda.dmt_Board.getAllBoardsInfo();
// Create a new board (optionally link to schematic/PCB)
return await eda.dmt_Board.createBoard();
// Switch to a document tab
await eda.dmt_EditorControl.activateDocument(tabId);
Example: Open a project by name and open its first schematic page
const targetProjectName = 'NE555 Circuit';
// 1. Enumerate projects by team/folder and find the target by name
const teams = await eda.dmt_Team.getAllTeamsInfo();
const seenProjectUuid = new Set();
let targetProjectUuid = null;
for (const team of teams || []) {
const teamProjects = await eda.dmt_Project.getAllProjectsUuid(team.uuid);
for (const projectUuid of teamProjects || []) {
if (seenProjectUuid.has(projectUuid)) continue;
seenProjectUuid.add(projectUuid);
const info = await eda.dmt_Project.getProjectInfo(projectUuid);
const name = info?.friendlyName || info?.name || '';
if (name === targetProjectName) {
targetProjectUuid = projectUuid;
break;
}
}
if (targetProjectUuid) break;
const folderUuids = await eda.dmt_Folder.getAllFoldersUuid(team.uuid);
for (const folderUuid of folderUuids || []) {
const folderProjects = await eda.dmt_Project.getAllProjectsUuid(team.uuid, folderUuid);
for (const projectUuid of folderProjects || []) {
if (seenProjectUuid.has(projectUuid)) continue;
seenProjectUuid.add(projectUuid);
const info = await eda.dmt_Project.getProjectInfo(projectUuid);
const name = info?.friendlyName || info?.name || '';
if (name === targetProjectName) {
targetProjectUuid = projectUuid;
break;
}
}
if (targetProjectUuid) break;
}
if (targetProjectUuid) break;
}
if (!targetProjectUuid) {
throw new Error(`Project not found: ${targetProjectName}`);
}
// 2. Open the project
const opened = await eda.dmt_Project.openProject(targetProjectUuid);
if (!opened) {
throw new Error(`Failed to open project: ${targetProjectName}`);
}
// 3. Get the first schematic page and open it
const schematics = await eda.dmt_Schematic.getAllSchematicsInfo();
if (!Array.isArray(schematics) || schematics.length === 0) {
throw new Error(`No schematics found in project: ${targetProjectName}`);
}
const firstSchematic = schematics[0];
const pages = await eda.dmt_Schematic.getAllSchematicPagesInfo();
const firstPage = (pages || []).find((page) => page.parentSchematicUuid === firstSchematic.uuid)
|| firstSchematic.page?.[0];
if (!firstPage) {
throw new Error(`No schematic page found in: ${firstSchematic.name}`);
}
const tabId = await eda.dmt_EditorControl.openDocument(firstPage.uuid);
return {
projectUuid: targetProjectUuid,
schematicUuid: firstSchematic.uuid,
pageUuid: firstPage.uuid,
tabId,
};
Notes:
dmt_Project.getAllProjectsUuid()is not a global no-arg enumerator in practice. To reliably find a project by name, iterate teams first, then folders.openProject(projectUuid)may discard unsaved changes in the currently opened project. Be careful before calling it.
PCB Primitive Operations
// Get selected primitives
const selected = eda.pcb_SelectControl.getAllSelectedPrimitives_PrimitiveId();
// Create a line on copper layer
// Layer parameter uses EPCB_LayerId enum — see references/enums/EPCB_LayerId.md
await eda.pcb_PrimitiveLine.create(
"GND", // net (string)
EPCB_LayerId.TOP, // layer — use enum, NOT raw number
0, // startX (unit: 1mil)
0, // startY (unit: 1mil)
1000, // endX (unit: 1mil)
0, // endY (unit: 1mil)
10, // lineWidth
false // primitiveLock
);
// Modify an existing primitive (async pattern)
const prim = await eda.pcb_PrimitiveComponent.get([id]);
const asyncPrim = prim.toAsync();
asyncPrim.setState_X(newX);
asyncPrim.setState_Y(newY);
asyncPrim.done();
PCB Async Primitive Pattern (IMPORTANT)
For modifying PCB/SCH primitives, you must use the async pattern:
// 1. Get the primitive
const prim = await eda.pcb_PrimitiveVia.get([viaId]);
// 2. Convert to async mode
const asyncPrim = prim.toAsync();
// 3. Set new values
asyncPrim.setState_X(newX);
asyncPrim.setState_Y(newY);
asyncPrim.setState_Diameter(diameter);
// 4. Apply changes
asyncPrim.done();
Schematic Operations
// Get all pages
return await eda.dmt_Schematic.getAllSchematicDocumentsInfo();
// Create a schematic component
// component parameter requires {libraryUuid, uuid} object — NOT a plain string
await eda.sch_PrimitiveComponent.create(
{ libraryUuid: "...", uuid: "device-uuid-from-library" }, // component object
5000, // x (unit: 0.01inch = 10mil)
5000, // y (unit: 0.01inch = 10mil)
"", // subPartName
0, // rotation (degrees, plain number)
false, // mirror
true, // addIntoBom
true // addIntoPcb
);
// Get selected schematic primitives
const ids = eda.sch_SelectControl.getAllSelectedPrimitives_PrimitiveId();
Library Operations
// List all libraries in workspace
return await eda.lib_LibrariesList.getAllLibrariesList();
// Search devices
return await eda.lib_Device.search("STM32");
// Get symbol info
return await eda.lib_Symbol.get(symbolUuid);
System Functions
// Show toast message
eda.sys_Message.showToastMessage("Operation complete!");
// Show confirm dialog
const confirmed = await eda.sys_Dialog.showConfirmationMessage("Proceed?");
// File system (limited to extension sandbox)
const content = await eda.sys_FileSystem.readFileFromFileSystem(path);
await eda.sys_FileSystem.saveFileToFileSystem(path, content);
DRC (Design Rule Check)
// Run DRC check
const passed = await eda.pcb_Drc.check(true, true, false);
// passed is boolean: true if DRC passed, false if errors found
Common Mistakes
Read API Signatures Carefully (CRITICAL)
Before calling ANY API method, you MUST read the full signature from references/ — including parameter types, return type, and remarks.
AI agents frequently make these errors due to skimming documentation:
Error 1: Not awaiting Promise-returning methods
Almost all EDA API methods return Promise<T>. If you forget await, you get a Promise object instead of the actual result.
// WRONG: Missing await — result is a Promise, not the project info
const project = eda.dmt_Project.getCurrentProjectInfo();
console.log(project); // Promise { <pending> }
// CORRECT: Always await async methods
const project = await eda.dmt_Project.getCurrentProjectInfo();
console.log(project); // { uuid: "...", name: "...", ... }
How to know if a method needs await: Check the return type in the signature. If it says Promise<...>, you MUST await it.
// From references/classes/DMT_Project.md:
getCurrentProjectInfo(): Promise<IDMT_ProjectItem | null>
// ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
// This is a Promise — you MUST await it
Error 2: Using raw numbers instead of enum values
Many parameters expect specific enum values. Using wrong numbers silently produces incorrect behavior.
// WRONG: What does layer "1" mean? Which copper layer? Signal? Mask?
await eda.pcb_PrimitiveLine.create("GND", 1, 0, 0, 1000, 0, 10, false);
// CORRECT: Use the enum — EPCB_LayerId.TOP is clear and type-safe
// Check references/enums/EPCB_LayerId.md for the correct value
await eda.pcb_PrimitiveLine.create("GND", EPCB_LayerId.TOP, 0, 0, 1000, 0, 10, false);
Always look up enums in references/enums/ before using numeric constants.
Error 3: Assuming parameter types without checking
Different APIs use different units, different ID formats, and different optional parameter conventions. Never assume.
// WRONG: Assuming create() parameters match modify() parameters
// create() and modify() often have DIFFERENT parameter orders/types
// CORRECT: Always read the exact signature for the method you're calling
// Check references/classes/<ClassName>.md for each method's specific signature
Summary — Before every API call:
- Read the signature — parameter types, return type, all in
references/classes/ awaitifPromise— check return type forPromise<...>- Use enums — look up in
references/enums/instead of guessing numbers/strings - Check remarks — the "备注" section often has critical usage notes
Coordinate Unit (CRITICAL)
Different domains use different coordinate units:
| Domain | Unit | Conversion |
|---|---|---|
| PCB | 1mil | 1mm ≈ 39.37 units |
| Schematic | 0.01inch (10mil) | 1mm ≈ 3.937 units |
This is the #1 mistake AI agents make. Mixing up the units will place components incorrectly.
- PCB: 1 unit = 1mil = 0.001 inch = 0.0254 mm
- Schematic: 1 unit = 0.01inch = 10mil = 0.254 mm
If you use the wrong unit, components will be placed 10x too far from their intended position.
// WRONG: thinking unit is 1mil (it's actually 0.01inch = 10mil)
// Placing at x=500 thinking it's 500mil = 0.5inch — but 500 units = 5000mil = 5inch!
await eda.sch_PrimitiveComponent.create({libraryUuid: "...", uuid: "dev-uuid"}, 500, 0, "", 0, false, true, true);
// CORRECT: 50 units = 500mil = 0.5inch (in 0.01inch units)
await eda.sch_PrimitiveComponent.create({libraryUuid: "...", uuid: "dev-uuid"}, 50, 0, "", 0, false, true, true);
Document State (CRITICAL)
After creating a project, you MUST open it before operating on documents within it.
When operating on documents, always verify:
- Project is opened — Use
eda.dmt_Project.getCurrentProjectInfo()to verify - Correct document is active — Use
eda.dmt_SelectControl.getCurrentDocumentInfo()to check document type - Document type matches API domain — PCB APIs require active PCB document, SCH APIs require active Schematic document
// WRONG: Assuming operation will work without checking document state
await eda.pcb_PrimitiveLine.create(...); // May fail if no PCB document is open
// CORRECT: Always verify document state first
const project = await eda.dmt_Project.getCurrentProjectInfo();
if (!project) {
// If you just created a project, you MUST open it before any operations!
return "Error: No project is currently opened. If you just created a project using dmt_Project.createProject(), you MUST call dmt_Project.openProject(projectPath) to open it first. You cannot operate on documents until a project is opened.";
}
const doc = await eda.dmt_SelectControl.getCurrentDocumentInfo();
if (doc?.documentType !== EDMT_EditorDocumentType.PCB) {
return "Error: No PCB document is currently active. Please open a PCB document first.";
}
// Now safe to perform PCB operations
await eda.pcb_PrimitiveLine.create(...);
Operating on the wrong document type will return errors or null results. For example:
- Executing
PCB_*APIs without an active PCB document (documentType !== EDMT_EditorDocumentType.PCB) → error/null - Executing
SCH_*APIs without an active Schematic document (documentType !== EDMT_EditorDocumentType.SCHEMATIC_PAGE) → error/null
IFrame Context — Always Use eda Directly (CRITICAL)
When writing extension code that creates an iframe via sys_IFrame.openIFrame(), the JavaScript code inside the iframe's HTML can access the eda global directly. Do NOT use window.parent.eda.
Why this matters:
EasyEDA injects the eda object into the iframe's execution context automatically. Standard browser cross-frame patterns (window.parent, parentWindow, etc.) do NOT apply here and will fail.
// WRONG: Using window.parent to reach parent frame's eda object
// This is a common mistake made by AI agents familiar with web iframe patterns
const project = await window.parent.eda.dmt_Project.getCurrentProjectInfo();
// CORRECT: eda is available directly in the iframe context
const project = await eda.dmt_Project.getCurrentProjectInfo();
This applies to ALL code inside sys_IFrame iframes:
- Extension UI panels loaded via
openIFrame() - Any HTML file inside the extension package displayed in an iframe
Rule: In EasyEDA extensions, whether code runs in the main context or inside an iframe created by sys_IFrame, always access the API through eda.xxx — never through window.parent.eda or any other parent frame accessor.
Multi-Window Support
When multiple EasyEDA windows are connected to the bridge, you do NOT need to check window selection on every EDA operation. Only check when:
- First EDA operation — Verify which window is active and tell the user
- EDA disconnected error — If bridge returns an error about EDA being disconnected, ask user to select a new window
Multi-window operations:
# List all connected EDA windows
curl http://localhost:49620/eda-windows
# Select a specific window
curl -X POST http://localhost:49620/eda-windows/select \
-H "Content-Type: application/json" \
-d '{"windowId": "abc-123-def"}'
# Execute on specific window
curl -X POST http://localhost:49620/execute \
-H "Content-Type: application/json" \
-d '{"code": "return await eda.dmt_Project.getCurrentProjectInfo();", "windowId": "abc-123-def"}'
If only one EDA window is connected, it's automatically selected as active.
Debugging Tips & Failure Strategies
Troubleshooting
- Always check health first: Scan ports 49620-49629 for
{"service":"easyeda-bridge"} - EDA not connected?: Ensure bridge extension is loaded in EasyEDA. Download: https://ext.lceda.cn/item/oshwhub/run-api-gateway
- Timeout errors: Default 30s timeout. If timeout occurs:
- Check if the correct project and document are opened (use
dmt_Project.getCurrentProjectInfo()) - If no project is opened, use
dmt_Project.openProject(projectPath)to open one - If no document is active, use
dmt_EditorControl.openDocument(docId)to open the correct document type (PCB/Schematic) - If the document type is wrong (e.g., running PCB APIs on Schematic), switch to the correct document first
- Complex operations may need code splitting
- Check if the correct project and document are opened (use
- Check return values: Many methods return
nullon failure — always validate - Layer numbers: Use enums from
references/enums/docs (e.g.,EPCB_LayerId) - EDA window disconnected: If you get an error about a window being disconnected, use
GET /eda-windowsto check available windows andPOST /eda-windows/selectto switch to another window - Permission errors: All API interfaces are controlled by EDA's permission system. If a specific API consistently fails to execute (returns error or null) while other APIs work fine, and you've confirmed the call matches the documentation exactly, it may be blocked by permissions — not a code bug. The EDA client may restrict certain operations based on user license, project settings, or document state. Inform the user that the operation may require elevated permissions or a different EDA edition.
- Persistent errors?: If you've verified the API call matches the documentation exactly, ruled out permission issues, and still encounter unexpected errors, consider reporting the issue through official EasyEDA support channels
Failure Handling Rules
When developing extensions, follow these rules:
| Situation | Action |
|---|---|
| API method does not exist in docs | Stop immediately — inform the user the API doesn't exist |
| Signature uncertain after reading docs | Stop generation — return to query step and re-read |
| Forbidden browser API detected | Auto-replace with eda.sys_* alternative |
| Menu ID conflict | Add prefix to differentiate (e.g., my-plugin-home, my-plugin-sch) |
| Permission blocked | Inform user — may require different EDA edition or license |
Critical: Never guess an API signature. If references/classes/ doesn't document it, it doesn't exist for your use case.
Workflow for AI Agent
When the user asks you to perform EDA operations:
- Understand the task — What domain? (PCB/SCH/LIB/Project)
- Verify document state — Check
eda.dmt_Project.getCurrentProjectInfo()andeda.dmt_SelectControl.getCurrentDocumentInfo() - Confirm correct document type — PCB operations need active PCB, SCH operations need active Schematic
- Look up API — Read relevant class docs from
references/ - Check types — Read enum/interface docs for parameter types
- Write code — Follow the execution context rules above
- Execute — Send via
POST /executeand check the result - Iterate — If errors occur, read error messages and adjust
When unsure about an API:
- Search
_quick-reference.mdfor method names - Read the specific class doc for detailed signatures and remarks
- Check interface docs for complex parameter types
Session Management
Detecting Topic Changes
The Bridge server consumes system resources while running. If the user has switched to a completely different topic (not related to EasyEDA/EDA/PCB/schematic) 3 consecutive times, proactively ask if they want to close the Bridge:
"I notice we've moved on from EasyEDA. The Bridge server is still running in the background. Would you like me to stop it to free up resources?"
Do NOT close the Bridge automatically — the user may switch back to EDA work later. Only ask, and close if they confirm.
Closing the Bridge
If the user confirms they want to stop the Bridge:
# Find and stop the bridge process
for port in $(seq 49620 49629); do
pid=$(lsof -ti :$port 2>/dev/null)
if [ -n "$pid" ]; then
kill $pid
echo "Bridge stopped (PID: $pid, Port: $port)"
break
fi
done